July 7, 2011
CSB: DuPont needs to 're-examine' safety practices
Lawrence Pierce
Chemical Safety Board member John Bresland addresses the media during a press conference in Charleston Thursday morning. At left is CSB Chairman Rafael Moure-Eraso.
Lawrence Pierce
A CSB photo poster shows, from top to bottom, the phosgene pipe that failed in a fatal January 2010 leak, a hose that had previously failed in the phosgene unit, and a new hose of the type DuPont used in the phosgene unit.
Advertiser

Read the report and updated coverage.

Phosgene plant could have left plant, crossed river, CSB says

CHARLESTON, W.Va. -- DuPont Co. rejected affordable plant and equipment upgrades, ignored near-miss incidents and violated the chemical giant's own widely touted safety guidelines in failing to prevent three January 2010 accidents that left one Belle plant worker dead, federal investigators said in a report issued Thursday.

U.S. Chemical Safety Board officials found common threads -- including poor maintenance practices, ineffective warning alarms, and insufficient accident investigations -- among the three incidents that occurred over a 33-hour period Jan. 22-23, 2010.

Chief among the findings was that nearly 25 years ago DuPont rejected proposals to enclose the Belle plant's phosgene unit, a move that would have protected workers and local residents from the poisonous material used as a chemical weapon in World War I.

CSB investigators also concluded that the most serious of the incidents, a fatal phosgene leak, was caused by the use of the wrong type of chemical hose and DuPont's failure to replace even that inadequate hose on its own required schedule.

"These kinds of findings would cause us great concern in any chemical plant -- but particularly in DuPont with its historically strong work and safety culture," said CSB member John Bresland, a longtime chemical plant manager and one-time DuPont lab technician. "In light of this, I would hope that DuPont officials are examining the safety culture company-wide."

Board Chairman Rafael Moure-Eraso said, "Tragedies can occur even with companies with highly-regarded safety cultures" and urged Kanawha Valley and West Virginia officials to create a local chemical plant accident prevention program.

DuPont officials said that they are reviewing the CSB report, but had already taken a variety of steps to improve safety procedures based on their own internal review of the incidents.

"Safety is a core value at DuPont and is our most important priority," company spokesman Dave Hastings said. "Our goal is zero -- meaning we believe all incidents and injuries are preventable."

In their 172-page report, CSB investigators focused on the Jan. 23, 2010, phosgene leak that killed plant worker Danny Fish. Agency experts also examined a methyl chloride leak that went on for five days before being discovered on Jan. 22, 2010, and a release of the chemical oleum the same morning as the deadly phosgene leak.

The report was issued in draft form. It won't be finalized until after a 45-day comment period that ends Aug. 22 and until the board approves the final version.

CSB officials found that the methyl chloride leak occurred when excess pressure caused a "rupture disc" to burst as designed to relieve that pressure.

The Gazette now offers Facebook Comments on its stories. You must be logged into your Facebook account to add comments. If you do not want your comment to post to your personal page, uncheck the box below the comment. Comments deemed offensive by the moderators will be removed, and commenters who persist may be banned from commenting on the site.
Advertisement - Your ad here